Field NotesPlant scienceNo. 05
What is VPD? Vapor pressure deficit for plants, explained
Relative humidity tells you how full the air is. VPD tells you how hard that air pulls water out of your plants, and you can work it out with a thermometer and a hygrometer.

The short answer VPD, or vapor pressure deficit, is the difference between how much water vapor the air could hold at its current temperature and how much it actually holds. It measures how hard the air pulls water out of leaves, which relative humidity alone can’t tell you, because the same humidity dries plants faster in warm air. Orchid and greenhouse guidance often cites about 0.5 to 1.2 kPa.
Your hygrometer reads 60%. Whether that’s humid or dry for your plants depends on the temperature. At 60°F, 60% relative humidity works out to a VPD of about 0.7 kPa. At 85°F, the same 60% is about 1.6 kPa, more than twice the drying pull.
VPD folds temperature and humidity into one number that tracks what the leaf actually experiences.
Why relative humidity alone is misleading
Relative humidity is a ratio: the water vapor actually in the air divided by the most the air could hold at that same temperature. The bottom half of that ratio changes quickly with temperature. Warm air holds far more water than cool air, roughly double for every 20°F (11°C) of warming.
So RH moves even when the amount of water in the air doesn’t. Outdoors, relative humidity typically peaks near sunrise and bottoms out in the early afternoon, mostly because the air warms, not because water left it.
An application note from greenhouse-controls maker Argus gives an example: hold RH at 75% and raise the temperature from 59°F to 95°F (15°C to 35°C), and VPD more than triples, from about 0.42 to 1.4 kPa.
What VPD actually measures
VPD is the saturation vapor pressure (what the air could hold) minus the actual vapor pressure (what it does hold). FAO’s crop water guide also calls it the saturation deficit. It’s usually given in kilopascals (kPa); some greenhouse controllers use millibars, where 10 mb equals 1 kPa.
A VPD of zero means the air is saturated, at its dew point. The bigger the number, the drier the air acts. A 2020 review in New Phytologist describes VPD as a direct measure of the atmosphere’s drying strength and notes that it climbs nonlinearly as temperature rises.
How VPD moves water and nutrients through a plant
Leaves lose water vapor through stomata, the same small pores they use to take in carbon dioxide. Higher VPD speeds up that transpiration, so the plant has to pull more water up from the root zone to keep pace.
That flow is also a delivery system. Minerals dissolved in the water travel with it, and Argus notes that when plants can’t evaporate enough water, minerals such as calcium don’t reach growing cells well.
The relationship has a ceiling. Transpiration rises with VPD only up to a point; beyond it, water loss levels off or falls as the plant closes its stomata. Still, warm, dry air generally means faster water use, which is part of why a fixed watering schedule can fall out of step as conditions change.
When VPD is too low
Very humid air slows transpiration. University of Arizona Extension lists the main costs: longer periods of leaf wetness that favor fungal and bacterial diseases, and, at extremely low VPD, suppressed transpiration that reduces nutrient movement inside the plant. The American Orchid Society (AOS) describes air below roughly 0.4 kPa as overly wet, with high disease pressure.
The plant also signals when it can’t shed water fast enough. Two signs to watch for:
- Guttation. Under low VPD, some plants push droplets of water out of their leaves.
- Edema (oedema). When soil is warm and moist and the air limits water loss, roots can take up more water than the leaves give off. Small, translucent, fluid-filled blisters form, mostly on the undersides of older leaves, and later scar into tan, corky patches. High humidity, low light, cool temperatures and poor ventilation all make it more likely.
The University of Wisconsin-Madison plant clinic suggests these fixes for edema: a well-draining mix, more space and air circulation between plants, more light and warmth, less frequent watering in cloudy, cool or humid spells, morning watering, and emptying saucers about 30 minutes after watering. If the mix stays wet for days, read overwatering vs. underwatering.
When VPD is too high
At the other end, the air pulls water out faster than roots can replace it. Plants respond by closing their stomata to limit the loss. That protects the plant’s water status but also cuts carbon dioxide uptake, so photosynthesis slows, and growth suffers if it lasts. Many species also curl their leaves or angle them downward to avoid wilting injury.
AOS treats air above roughly 1.5 kPa as overly dry. Outdoors it can run much higher: University of Arizona Extension reports a monthly mean VPD of about 3.8 kPa in July in Arizona’s Yuma Valley.
Target ranges, and who cites them
There’s no single correct VPD. It depends on the plant and its growth stage, and published figures are guidance, not rules.
- American Orchid Society: about 0.5 to 1.2 kPa for many thin-leaved orchids. AOS found no established orchid recommendations and drew on Michigan State University greenhouse research.
- Greenhouse propagation and finishing (as summarized by AOS): a fairly low VPD, around 0.3 kPa, while rooting cuttings, and above 0.5 kPa while finishing plants, a figure AOS attributes to Michigan State Extension.
- Argus Control Systems: uses 5 to 12 mb (0.5 to 1.2 kPa) as an example “ideal” band, noting that it was chosen for an imaginary crop and that growers must set numbers for their own plants.
Treat 0.5 to 1.2 kPa as a reasonable middle band, then watch how your plants respond.
How to estimate VPD at home
You need air temperature and relative humidity, measured where the leaves are. Put a thermometer-hygrometer at canopy height, close to the plants and shaded from direct sun or a grow light. Argus recommends a sensor in or near the canopy, with air drawn across it, as a practical stand-in for leaf conditions.
Then work it out in three steps, with temperature (T) in °C (subtract 32 from °F and multiply by 5/9).
- Saturation vapor pressure, in kPa, using the Tetens form from the FAO guide: es = 0.6108 × exp(17.27 × T / (T + 237.3))
- Actual vapor pressure: ea = es × RH / 100
- VPD = es − ea
Worked example: 77°F (25°C) at 60% RH.
- 17.27 × 25 = 431.75, and 25 + 237.3 = 262.3. Dividing gives 1.646.
- exp(1.646) = 5.186, and 5.186 × 0.6108 = 3.168 kPa. That matches FAO’s own worked figure for 25°C.
- ea = 3.168 × 0.60 = 1.901 kPa.
- VPD = 3.168 − 1.901 = 1.27 kPa.
Here is a small VPD chart computed the same way (air VPD, in kPa):
| Air temperature | 40% RH | 50% RH | 60% RH | 70% RH | 80% RH |
|---|---|---|---|---|---|
| 60°F (15.6°C) | 1.06 | 0.88 | 0.71 | 0.53 | 0.35 |
| 65°F (18.3°C) | 1.26 | 1.05 | 0.84 | 0.63 | 0.42 |
| 70°F (21.1°C) | 1.50 | 1.25 | 1.00 | 0.75 | 0.50 |
| 75°F (23.9°C) | 1.78 | 1.48 | 1.19 | 0.89 | 0.59 |
| 80°F (26.7°C) | 2.10 | 1.75 | 1.40 | 1.05 | 0.70 |
| 85°F (29.4°C) | 2.47 | 2.05 | 1.64 | 1.23 | 0.82 |
At 70°F, staying between 0.5 and 1.2 kPa takes roughly 52 to 80% RH. At 40% RH, the same room sits at 1.5 kPa.
To skip the arithmetic, the VPD calculator runs all three steps for any reading, including leaf VPD.
Leaf temperature vs. air temperature
Everything above is air VPD. What a leaf feels depends on its own temperature, because the air inside a leaf is treated as saturated at leaf temperature. Researchers often use leaf-to-air VPD for that reason: vapor pressure inside the leaf minus that of the surrounding air. A leaf can run warmer or cooler than the air, depending on how much radiation it absorbs and how much transpiration cools it.
Take the same room as the worked example (77°F, 60% RH, so ea = 1.901 kPa), but say the leaf is 3.6°F (2°C) cooler. At 23°C, es is 2.809 kPa, so leaf VPD is 2.809 − 1.901 = 0.91 kPa, versus 1.27 kPa for the air. A leaf 2°C warmer than the air would see about 1.66 kPa.
To use leaf temperature, calculate ea from the air reading as usual, then es from a leaf reading (an infrared thermometer works). Argus notes that leaf temperatures vary a lot across a crop and are seldom practical to track, so a canopy air reading is a reasonable default. Either way, measure at the same spot and time of day so your numbers stay comparable. Leaf temperature is also a direct read on water stress in the plant itself, which how to measure plant water stress covers.
Sources
- Chapter 3 - Meteorological dataFood and Agriculture Organization of the United Nations (FAO Irrigation and Drainage Paper 56)
- Plant responses to rising vapor pressure deficitNew Phytologist (Grossiord et al., 2020), author copy hosted by UC Davis
- What the Air Is Telling You: Understanding Vapor Pressure Deficit and Why It Matters in Yuma AgricultureUniversity of Arizona Cooperative Extension
- Understanding and Using VPDArgus Control Systems (application note)
- Humidity and Vapor Pressure DeficitAmerican Orchid Society
- EdemaUniversity of Wisconsin-Madison Plant Disease Diagnostics Clinic
General information, not professional advice for a specific plant or crop. Spot something wrong? Email info@terrathink.io.


