ToolsCalculator

PPFD, lux and DLI calculator

Turn a light meter reading into the numbers plants respond to: photons arriving each second (PPFD) and the day's total (DLI).

h

PPFD

93µmol/m²/s

DLI in Iowa State's low range (3 to 6): many foliage houseplants.

Lux
5,000
Foot-candles
465
Daily light integral
4.0 mol/m²/day

Plan a grow light

mol/m²/day
h

PPFD to aim for at the leaves

139µmol/m²/s

About 7,500 lux under the light source picked above.

The short answer To estimate PPFD from a lux reading, multiply by a factor that depends on the light source: 0.0185 for sunlight, by Apogee Instruments’ figures. Daily light integral (DLI) is PPFD × hours of light × 0.0036. LED grow lights vary too much for one factor, so measure them with a quantum (PAR) sensor.

How to use it

Enter one reading, in lux, foot-candles or PPFD, and pick the light source it was taken under. The calculator fills in the other two units. Add how many hours a day the plant gets that light to see the DLI.

To plan a grow light instead, use the second panel: enter the DLI you want and the hours the light will run, and it gives the PPFD to aim for at the leaves.

Why lux and PPFD don’t convert with one number

Lux is built around human vision. The lumen is defined at about 555 nm, near the peak of the eye’s sensitivity, so lux counts yellow-green light heavily and red and blue light less. PPFD counts every photon between 400 and 700 nm equally, in µmol/m²/s. A lamp that looks bright to you can deliver fewer usable photons than a dimmer-looking one, so the conversion changes with the spectrum.

Apogee Instruments publishes these factors. Multiply lux by the first number to get PPFD, or multiply PPFD by the second to get lux:

Light source Lux to PPFD PPFD to lux
Sunlight 0.0185 54
Cool white fluorescent 0.0135 74
Metal halide 0.0141 71
Ceramic metal halide, 4200 K (CMH942) 0.0154 65
Ceramic metal halide, 3100 K agro (CMH930) 0.0170 59
High pressure sodium, mogul base 0.0122 82
Double-ended high pressure sodium (1000 W) 0.0130 77

One foot-candle is 10.76 lux (Iowa State). So 5,000 lux of daylight is about 93 µmol/m²/s, but under cool white fluorescent tubes it’s only about 68.

LED grow lights aren’t on Apogee’s list, and their spectra vary widely. If your light’s maker publishes a lux-to-PPFD factor, enter it under Custom; otherwise a quantum sensor is the reliable way to measure it.

From PPFD to DLI

PPFD is a rate, like a speedometer. DLI is the day’s total, like a trip odometer, in mol/m²/day. For a light with steady output, Iowa State gives:

DLI = PPFD × hours × 0.0036

A grow light delivering 200 µmol/m²/s for 16 hours works out to about 11.5 mol/m²/day (Virginia Tech’s example). Working backward, 6 mol/m²/day over 12 hours takes about 140 µmol/m²/s at the leaves.

Daylight isn’t steady, so a single midday reading multiplied by the day length overstates DLI. For a window, take several readings through the day, or use a sensor that logs light over time.

How much light houseplants need

Light level Foot-candles at the leaves (Missouri) DLI, mol/m²/day (Iowa State)
Low 50 to 250 3 to 6
Medium 250 to 1,000 6 to 10
High 1,000 or more 12 to 16

Iowa State puts foliage houseplants in the low and medium DLI groups, flowering houseplants in medium and high, and succulents in high. Missouri Extension notes that even low-light plants usually don’t get enough light more than 10 feet from an average window. How much light does a houseplant need? covers window direction, distance and grow lights in more detail.

Getting a reading worth converting

Phone light-meter apps are least reliable in dim light, exactly where low-light decisions get made. In a 2017 study in Applied Sciences, one uncalibrated phone sensor was off by about 39% on average against a reference lux meter, and by about 62% below 100 lux, though under 5% above 500 lux. The study tested only three phones under one incandescent bulb. Use the same phone, held the same way, to compare spots against each other, or use a handheld light meter.

Sources

  1. PPFD to Lux ConversionApogee Instruments
  2. Important Considerations for Providing Supplemental Light to Indoor PlantsIowa State University Extension and Outreach
  3. Calculating and Using Daily Light Integral (DLI): An Introductory GuideVirginia Cooperative Extension (Virginia Tech)
  4. Lighting Indoor Houseplants (G6515)University of Missouri Extension
  5. Smartphones as a Light Measurement Tool: Case of StudyApplied Sciences 7(6):616 (2017), MDPI

Estimates for general guidance, not professional advice for a specific plant or crop. Spot something wrong? Email info@terrathink.io.

Related field notes

All field notes

More tools

All tools

Join the waitlist

New field notes by email, and first word when the hardware goes live.

By joining, you agree to get email updates from Terrathink. Unsubscribe anytime. Privacy policy