ToolsCalculator

EC to ppm converter

Two meters can show different ppm for the same water. Convert between EC and every common ppm scale, and see where your reading falls.

Each sampling method has its own scale, so the same number can mean different things.

°C

Corrects the reading to 25 °C at 2% per °C, typical for neutral salts by Hanna Instruments' figures.

EC

1.50mS/cm

In Oklahoma State's range for basil and lettuce; below tomato.

µS/cm
1,500
ppm, 500 scale
750
ppm, 650 scale
975
ppm, 700 scale
1,050

The short answer The ppm on a nutrient meter isn’t measured; it’s calculated: ppm = EC in mS/cm × the meter’s scale, usually 500, 650 or 700. So 1.5 mS/cm reads 750 ppm on the 500 scale and 1,050 ppm on the 700 scale. Meter maker Bluelab recommends working in EC, which means the same thing on every meter.

How to use it

Enter a reading and pick its unit: EC in mS/cm or µS/cm, or ppm on one of the three scales. The calculator converts it to all the others. Then tell it how the sample was taken, from a hydroponic solution or from potting mix by one of three test methods, to see where the number sits in published ranges.

The units

EC (electrical conductivity) measures dissolved salts, mostly fertilizer. Horticulture usually reports it in mS/cm, and UMass Extension notes that 1.0 mS/cm is the same as 1.0 dS/m and 1.0 mmho/cm. Some meters show µS/cm, a thousandth of a mS/cm, so the number is 1,000 times larger: 1.41 mS/cm is about 1,413 µS/cm (Michigan State University Extension).

The ppm scales

Bluelab names three ppm scales in wide hydroponic use:

  • 500 scale, also called TDS, based on sodium chloride
  • 650 scale, which Bluelab mainly associates with the United States
  • 700 scale, based on potassium chloride

Bluelab says a US feeding chart could use the 650 or 500 scale, and a UK chart the 700. Its worked example: 2.4 EC is 1,200 ppm on the 500 scale and 1,680 on the 700 scale. True ppm takes a chemical analysis; an EC meter can’t measure it. If a chart gives a target in ppm, find out which scale it uses before you mix.

EC (mS/cm) EC (µS/cm) 500 scale 650 scale 700 scale
0.5 500 250 325 350
1.0 1,000 500 650 700
1.5 1,500 750 975 1,050
2.0 2,000 1,000 1,300 1,400
2.5 2,500 1,250 1,625 1,750
3.0 3,000 1,500 1,950 2,100

Where your number falls

The right EC depends on what you sampled and how. For hydroponic solutions, Oklahoma State Extension gives optimum ranges by crop, including 1.0 to 1.6 mS/cm for basil, 1.2 to 1.8 for lettuce and 2.0 to 4.0 for tomato.

For potting mix, each test method has its own scale. Purdue Extension’s “normal” bands for most established plants are 2.7 to 4.6 mS/cm by PourThru, 2.1 to 3.5 by saturated media extract (SME) and 0.76 to 1.25 by 1:2 dilution. A PourThru reading of 3.0 is normal; by 1:2 the same number is extreme. Sources differ, too: UMass Extension’s lab calls 1.5 to 3.0 normal by saturated paste. EC and pH for plants walks through each method and what to do when a reading is off.

Temperature and calibration

A cold solution conducts less. For neutral salts the change is typically 1.5 to 2.2% per °C, according to Hanna Instruments, so a solution 10 °C below the reference temperature reads about 20% low on a meter without compensation, at 2% per °C. Meters with automatic temperature compensation correct to a reference temperature, typically 25 °C or 20 °C. If yours doesn’t, enter the solution temperature and the converter corrects the reading to 25 °C with linear compensation, EC25 = EC ÷ (1 + 0.02 × (T − 25)), using 2% per °C.

Calibrate EC meters with a standard solution, usually 1.41 mS/cm (Oklahoma State), which may be labeled 1,413 µS/cm.

Sources

  1. What are the different conductivity scales? What do they mean?Bluelab Support
  2. Soil Test Report - Commercial FloricultureUMass Extension
  3. Calibrate your pH and EC meter in your greenhouseMichigan State University Extension (Wollaeger, 2016)
  4. Electrical Conductivity and pH Guide for HydroponicsOklahoma State University Extension (Singh and Dunn)
  5. HO-237: pH and Electrical Conductivity Measurements in Soilless SubstratesPurdue University Extension, Horticulture and Landscape Architecture (Camberato, Lopez and Mickelbart)
  6. Why do I need temperature compensation for measuring EC?Hanna Instruments Knowledge Base

Estimates for general guidance, not professional advice for a specific plant or crop. Spot something wrong? Email info@terrathink.io.

Related field notes

All field notes

More tools

All tools

Join the waitlist

New field notes by email, and first word when the hardware goes live.

By joining, you agree to get email updates from Terrathink. Unsubscribe anytime. Privacy policy